RTX-300 Typical Performance

RTX-300 Performance Test data provided by The University of Arkansas Civil Engineering Dept.
Tests conducted on T1-55, an earlier, single strength, version.

SAMPLE TEST RESULTS - LAOS

SUMMARY OF TEST RESULTS ON T1-55* APPLICATION FOR IMPROVEMENT OF THE EXISTING ROAD MATERIALS AT BAN NONG TO DING XUANG ROAD SECTION (6 KM) IN SALAVANH PROVINCE - LAOS PEOPLE’S DEMOCRATIC REPUBLIC

*T1-55 was an earlier version of RTX-300 Maximum Strength.
Sample No. Site Class Kind of Test AASHTO Untreated Treated Improvement
1 KM5+900
A-7-6
GRADING T88 SEE GRADING CURVE - -
LL T90 47 45 DECREASED 4%
PI T90 34 11 DECREASED 54%
MDD-OMC T181 1.98g/cm3-11% - -
SOAK/CBR T193-81 10% 49% INCREASED 490%
UCS 497.26Kps 1777.14Kps INCREASED 365%
Sample No. Site Class Kind of Test AASHTO Untreated Treated Improvement
2 KM4+900
A-7-6
GRADING T88 ALL PASSED SIEVE 0.075 - -
LL T90 64 54 DECREASED 16%
PI T90 26 16 DECREASED 39%
MDD-OMC T181 1.688g/cm3 -16.8% - -
SOAK/CBR T193-81 4% 35% INCREASED 875%
UCS 316.96 Kps 1763.90Kps INCREASED 557%
Sample No. Site Class Kind of Test AASHTO Untreated Treated Improvement
3 KM2+500
A-7-6
GRADING T88 ALL PASSED SIEVE 0.075 - -
LL T90 64 50 DECREASED 22%
PI T90 25 14 DECREASED 44%
MDD-OMC T181 1.694 g/cm3 - 16.8% - -
SOAK/CBR T193-81 5% 36% INCREASED 720%
UCS 323.29 Kps 1801.43Kps INCREASED 557%